Search results for "Implant loading"
showing 10 items of 20 documents
Bone loss around narrow implants versus standard diameter implants: Retrospective 2-years case-control study
2019
Background The objectives were to evaluate the bone loss (BL) around narrow diameter implants (3.3 mm) 2 years after implant loading and compare with the bone loss around conventional-diameter implants (4.1 mm), as well as with clinical and anatomical variables. 2-years follow-up. Material and Methods Cases: 20 patients either gender-age, narrow implants (Straumann TM-SLA, diameter 3.3 mm); Control: 20 patients matching for gender-age, conventional implants (Straumann TM-SLA, diameter 4.1). Total 82 implants (31 narrow implants and 51 conventional implants) in 40 patients. To avoid statistical bias, a cluster of one implant per patient was randomly selected (20 narrow implants and 20 conven…
Maintenance of marginal bone support and soft tissue esthetics at immediately provisionalized OsseoSpeed implants placed into extraction sites: 2-yea…
2012
Background Placement of implants into extraction sockets targets the maintenance of peri-implant hard and soft tissue structures and the support of a natural and esthetic contour. The main advantages of immediate implant insertion in comparison with delayed implant placement protocols are as follows: a reduced treatment time, less number of sessions, and, thus, the less invasive procedure. This study examines the clinical performance (survival rate, marginal bone levels and Pink Esthetic Score [PES]) of OsseoSpeed™ implants placed into extraction sockets with immediate provisionalization in the anterior maxilla after a follow-up of at least 12 months. Methods Twenty patients received a tota…
Clinical and esthetic outcome with immediate insertion and provisionalization with or without connective tissue grafting in presence of mucogingival …
2017
Background Recessions following immediate implant insertion are frequently reported in the literature. Data regarding implant installation in presence of mucogingival recessions are rare. Purpose This study observes soft tissue level changes following immediate implant insertion and provisionalization of implants with or without connective tissue grafts in the anterior maxilla in patients with initial mucogingival recession within a follow-up period between one and eight years. Materials and methods Twenty-six patients with marginal gingival recessions, which were designated for extraction and immediate implant insertion in the anterior zone of the maxilla (13-23), were included. Out of a l…
Immediately provisionalized OsseoSpeed(™) Profile implants inserted into extraction sockets: 3-year results.
2015
Objectives A sloped shoulder might improve the congruence between extraction socket and dental implant and may add to a better circumferential support of the peri-implant structures. Therefore, this study evaluates the 3-year clinical outcome (survival and success rates, marginal bone levels, and Pink Esthetic Score (PES)) of immediately inserted and provisionalized OsseoSpeed(™) Profile implants in the anterior maxilla. Material and methods Twenty-one implants were inserted in 16 patients. All implants were immediately placed into extraction sites with and without facial bone deficiencies. A flapless procedure was utilized, and the implants were provisionalized immediately. Facial gaps wer…
Survival rates and bone loss after immediate loading of implants in fresh extraction sockets (single gaps). A clinical prospective study with 4 year …
2016
Background The aim of this prospective study was to report the outcome of treatment with implants inserted after tooth extraction and immediately loaded. Material and Methods Fifty-six patients with single tooth loss were treated with 116 IPX Galimplant® implants with internal connections and a sandblasted, acid-etched surface. All implants were placed after tooth extraction using a flapless approach without bone regeneration, and they were then immediately loaded with cemented acrylic prostheses. After a period of three months, definitive cemented ceramic prostheses were placed. Patients were examined throughout a total of 4 years of follow-up. Marginal bone loss and survival rates were ev…
Influence of soft tissue grafting, orofacial implant position, and angulation on facial hard and soft tissue thickness at immediately inserted and pr…
2018
Background Resorption of hard and soft tissues following immediate implant insertion is frequently reported. Data regarding the influencing factors on facial tissue thickness are rare. Purpose This retrospective study investigated the impact of connective tissue grafting, the orofacial angulation and position of immediately inserted and provisionalized implants on the facial hard and soft tissue thickness in the anterior maxilla within a 1- to 5-year follow-up. Material and methods Implants with the prerequisite of having preoperative and postoperative cone beam computed tomography (CBCT) and a follow-up of 1 to 5 years were included. Facial bone deficiencies were grafted flaplessly with au…
Use of buccal fat pad to repair post-extraction peri-implant bone defects in the posterior maxilla: a preliminary prospective study
2015
Background: Extensive literature exists about the use of the BFP in the treatment of oral defects but, to our knowledge, no article refers to the use of the BFP as a substitute of the membrane barriers for treatment of peri- implant bone defects. The aim was to evaluate the use of the buccal fat pad as a coating material for bone grafting in the peri-implant bone defect regeneration of immediate implants placed in the posterior maxilla. Material and Methods: A preliminary prospective study of patients involving immediate implants in which the buccal fat pad was used as a coating material to peri-implant bone defects was carried out. The outcome measures assessed were: postoperative pain and…
A Prospective Noninterventional Study to Evaluate Survival and Success of Reduced Diameter Implants Made From Titanium-Zirconium Alloy
2015
Narrow diameter implants may be at increased risk of overload due to occlusal forces; therefore, implants with higher fatigue strength may be beneficial. The aim of this observational study was to evaluate survival and success of narrow diameter (Ø 3.3 mm) TiZr alloy (Roxolid, Institut Straumann AG, Basel, Switzerland) implants for 2 years in daily dental practice. This was a prospective, non-interventional, multicenter study; no specific patient inclusion or exclusion criteria were applied. Each patient received at least one TiZr implant; the treatment plan, including implant loading and final restoration, was at the investigator's discretion. The primary outcome was implant survival and s…
Immediate dental implants placed into infected sites present a higher risk of failure than immediate dental implants placed into non-infected sites: …
2019
Background Alveolar infection is known as a risk factor for implant failure. Current meta-analysis on the theme could not prove statistically that immediate dental implants placed into infected sites have a higher risk of failure than immediate dental implants placed into non-infected sites. The purpose of this meta-analysis was to determine the effectiveness of immediate dental implants placed into infected versus non-infected sites. Material and Methods Seven databases were sought by two reviewers. Randomized or non-randomized clinical trials that compared the placement of dental implants into infected versus non-infected sites were eligible for the study. Exclusion criteria were: papers …
Immediate and flapless implant insertion and provisionalization using autogenous bone grafts in the esthetic zone: 5-year results.
2017
Objectives As the 2-year results for immediately inserted and provisionalized implants have been reported, it remained an open issue, whether the initially high success rates and the esthetic outcome remain stable for longer observation periods. Therefore, this prospective study examines the 5-year hard and soft tissue changes at implants placed in the anterior maxilla. Material and methods Meanwhile, 37 microthreaded implants were placed in 21 patients into extraction sockets with and without facial bone deficiencies by a flapless approach. Facial gaps and bony defects were grafted with autogenous bone chips. The implants were immediately provisionalized. The primary outcome parameters wer…